Dimensions

ModelTotal lengthHeated lengthTube dia.Wall
IR-31953195 ± 0.5 mm2900 mmΦ30 ± 0.2 mm3 mm
IR-36203620 ± 0.5 mm2720 mmΦ30 ± 0.2 mm3 mm

Material / 材质

ParameterValue
Tube materialHigh-purity 4N low-OH quartz tube
SiO₂ content≥ 99.99%
Hydroxyl (OH) content≤ 5 ppm
CoatingUncoated

Electrical / 电气

ParameterValue
Rated voltageAC 380 V ±10%
Rated powerCustomised to order, deviation ≤ ±3%
Cold insulation resistance≥ 100 MΩ (500 V DC)
Dielectric strength1500 V AC / 1 min, no breakdown, no flashover
Heating elementNi-Cr alloy wire

Thermal performance / 热性能

ParameterValue
Continuous operating temperatureUp to 450 °C
Temperature uniformity≤ ±2 °C between any two points
Uniformity test distance70 mm from lamp surface
Thermal response time≤ 60 s

Sag / 下垂量(Φ30 tube)

ParameterValue
At room temperature≤ 2.5 mm
At full power≤ 4 mm
Test conditionSupported 30 mm inboard from each end

Service life / 寿命

ParameterValue
Design continuous life≥ 40,000 h (approx. 5 years)
Power decay at 40,000 h≤ 20%
Operation modeContinuous, non-stop
Process cycle260 min per cycle

Process cycle temperature profile (260 min)

Process temperatureShare of cycle
100 °C28%
150 °C22%
250 °C30%
450 °C19%
500 °C0.9%
750 °C0.1%

Referenced standards

Before You Order: Six Checks

You do not need to read every datasheet first — run through these six points in order.

1 · Total length and heated length
Two numbers, not one: the overall length that must fit your machine and the zone that must actually radiate. Standard sizes are 3195 mm / 2900 mm and 3620 mm / 2720 mm.
2 · Tube diameter and wall
Φ30 mm tube with 3 mm wall is our standard. Confirm the mounting clamps and the free space around the lamp before changing diameter.
3 · Supply voltage and power
Lamps run on AC 380 V ±10%. Rated power is built to your order with deviation ≤ ±3% — tell us the power you need, not the power you think we stock.
4 · Process temperature and cycle
Send the working temperature and the cycle time. Our reference duty is 260 min per cycle with 100–500 °C steps; uniformity is held to ≤ ±2 °C at 70 mm from the surface.
5 · Mounting, support and sag
With supports 30 mm inboard from each end, sag is ≤ 2.5 mm cold and ≤ 4 mm at full power. Confirm the support points and the clearance to the product or reflector.
6 · Life, quantity and spares
Design continuous life is ≥ 40,000 h (about 5 years) with power decay ≤ 20%. Tell us the quantity and the maintenance window so spares can be shipped together.

Not sure about one of them? Send the data you have — drawings, photos or a nameplate are enough to start. Send your requirement →

Ordering & Delivery

Warranty is a guaranteed minimum period. Design life under continuous operation is a separate figure — see technical data.

Warranty3,000 hours — medium-wave infrared heating lamps
Payment100% before shipment
Lead timeConfirmed per model and quantity

Get a Quote

Talk to an engineer